Telaire-duct-smoke-detector-manual, superduct four-wire duct smoke detector 3 duct and is directed back into the ventilation system through an exhaust tube. the difference in air pressure between the two tubes pulls the sampled air through the sensing chamber. when a sufficient amount of smoke is detected in the sensing chamber, the sensor signals an alarm state and the controller. Telaire has been on the forefront of co2 sensing technology for over 25 years and holds 30+ awarded patents in co2 sensing, including the original automatic calibration algorithm - abc logic®. in more recent years, telaire has expanded its product line to include other air quality sensors, including dust (pm2.5 and pm10) and relative humidity (rh) sensors., telaire tsd-cj-c01 control smoke detector carrier module duct hk28zt001.

The telaire t6700 series of co 2 sensor modules is designed for applications that require high accuracy in a compact package. they are ideal for use where co 2 levels need to be measured and controlled for indoor air quality and energy saving applications, such as demand control ventilation., superduct four-wire controller (rj-45 version) 3 / 4 controller to sensor wiring connect the controller to the sensor as shown in figure 5. make sure the cable grommets are seated securely into their respective openings. first sensor controller optional second sensor rj-45 cable assembly (ordered separately) rj-45 cable assembly (ordered ....

©2006 system sensor. product specifications subject to change without notice. visit systemsensor.com for current product information, including the latest version of this data sheet. a05-1044-007 • 7/06 • #1676 ordering information part no. description dh100acdclp 4-wire photoelectric duct detector with low-flow technology, telaire tsd-sj-c01 2v781897 edwards superduct photoelectric smoke sensor wire 793016046895 4 rj-45. Installation instructions remote keyed attenuator sd–trk4 for factory---installed smoke detectors commercial rooftop unit 2---25 tons important: read these instructions completely before attempting to install the accessory remote keyed attenuator. safety considerations installation and servicing of air--conditioning equipment, crsmkkit002a00 crsmksen002a00 installation instructions fieldinstalledsmokedetectors for medium rooftop units 15 to 25 tons table of contents package contents 1......

View and download carrier 48/50a020-060 installation instructions manual online. accessory return smoke detectors for 48/50a020-060, 48/50z030-105 single-package rooftop units. 48/50a020-060 smoke alarm pdf manual download. also for: 48/50z030-105, crsmkdet002c00.